+8618700875368

Thermal Abuse Chamber for Battery Explosion Protection Testing

Jul 28, 2025

LIB's Thermal Abuse Chambers combine multi-layer explosion protection, real-time smoke/temperature monitoring, rapid exhaust, and built-in fire suppression to safely test batteries from –70 °C to +150 °C. Highprecision PT100 Class A probes with PID control maintain ±0.5 °C stability, all managed via touchscreen or remote network.

 

Complementing this, LIB offers –70 °C to +200 °C Thermal Shock Chambers, IEC 60529 IPX1–IPX9K Waterproof Test Chambers, and vertical and horizontal Vibration Systems. Modular designs-benchtop to walk-in, custom cable holes, and racks-deliver a turnkey batterysafety lab for reliability, sealing, and mechanical testing under the harshest conditions.

 

【Reliable Battery Explosion Protection of The LIB Thermal Abuse Chamber】

To meet the safety testing requirements for batteries under extreme high temperature conditions ranging from -70°C to +150°C, LIB has comprehensively upgraded its explosion protection system in the thermal abuse test chamber:

 

1. Multi-layered explosion-proof structure

 

Explosion-proof inner chamber: Constructed using SUS304 stainless steel plates, it remains intact even under the intense pressure impact caused by thermal runaway.

 

Explosion-proof door and observation window design: The viewing window features dual reinforcement with multi-layer tempered glass and stainless steel mesh. The door is equipped with a dedicated explosion-proof lock, capable of withstanding an impact pressure of up to 0.5 bar during an explosion without rupturing.

 

2. Active Monitoring and Ventilation

 

Dual smoke and temperature sensor monitoring: Multiple smoke sensors (sensitivity ≤ 0.08 dB/m) and temperature probes are installed on the top and side walls of the chamber, providing real-time feedback on any thermal runaway events.

 

Automatic exhaust valves: Upon detecting excessive smoke concentration or sudden temperature changes, the system immediately opens the exhaust valves (maximum exhaust airflow 500 m³/h) to rapidly remove harmful gases and reduce internal pressure.

 

3. Built-in Fire Suppression System

Water-based fire suppression: Equipped with a sprinkler system that can cover the entire chamber within 3 seconds to suppress initial flam.

 

【Precise Temperature Control and Convenient Operation of LIB Thermal Abuse Chamber】

Model

TH-100

TH-225

TH-500

TH-800

TH-1000

Internal Dimension (mm)

400*500*500

500*600*750

700*800*900

800*1000*1000

1000*1000*1000

Overall Dimension (mm)

900*1050*1620

1000*1140*1870

1200*1340*2020

1300*1540*2120

1500*1540*2140

Interior Volume

100L

225L

500L

800L

1000L

Heat load

1000W

Temperature Range

A : -20℃ ~ +150 ℃

B : -40℃ ~ +150 ℃

C: -70℃ ~ +150 ℃

Temperature Fluctuation

± 0.5 ℃

Temperature Deviation

± 2.0 ℃

Humidity Range

20% ~ 98% RH

Humidity Deviation

± 2.5% RH

Cooling Rate

1 ℃ / min

Heating Rate

3 ℃ / min

 

1. High-precision temperature control

PT100 Class A sensor: Complies with IEC 60751 standards, with a resolution of up to 0.001°C, providing accurate feedback of actual temperature.

 

PID Controller: Integrated with the sensor to ensure temperature fluctuation ≤ ±0.5°C and deviation ≤ ±0.2°C.

Thermal Abuse Chamber

2. User-Friendly Controller Operation

 

7-inch Color Touchscreen: Intuitive interface supporting multi-language switching and graphical curve display;

 

Remote Monitoring: Built-in Ethernet, RS-485 (Modbus-RTU), and USB ports enable real-time data collection and alarm notifications;

 

Rich Program Management: Can store up to 120 test programs, with each program supporting up to 100 segments, including settings for loop counts and delayed starts.

Thermal Abuse Chamber

 

3. Typical Application Scenarios

 

Battery Cell Thermal Runaway Threshold Testing: Set multi-segment temperature-rising programs to precisely identify the thermal runaway critical points of battery cells at different temperatures;

 

Large-Scale Cycling Reliability Validation: Continuous automatic operation; engineers can view real-time curves and export reports from the office.

 

【LIB offers various test chambers for battery safety: thermal abuse, thermal shock, IP waterproof, and vibration systems】

 

1. Thermal Shock Chamber

–70°C to +200°C rapid switching test to evaluate the structural stability of batteries and their components in extreme hot and cold alternating environments; supports dual-zone (2-zone) and triple-zone (3-zone) configurations, with capacity customizable based on sample volume and temperature difference multiples.

 

2. IP Waterproof Test Chamber

Meets IEC 60529 IPX1–IPX9K rating test requirements; offers multiple rain spray, immersion, and high-pressure water jet modes to evaluate the waterproof sealing performance of battery packs and connectors.

 

3. Vibration Test Chamber

Vertical and horizontal vibration testing simulates vibrations during transportation, assembly, or earthquakes; can be combined with temperature and humidity environments for comprehensive temperature, humidity, and vibration testing to accurately replicate the comprehensive reliability of batteries under extreme conditions.

 

4. Customization Capabilities

Interfaces: Cable holes, test chamber dimensions, sample shelves shapes and sizes, etc., can be customized from bench-top to walk-in configurations.

 

 

LIB offers a 3-year warranty and lifetime service. Any issues that cannot be resolved during the warranty period will be replaced free of charge. 24/7 English-speaking after-sales team. Fast shipping within 7-15 days.

 

Contact LIB to develop a professional and efficient solution tailored to your specific standards and stringent requirements.

 

Send Inquiry