+8618700875368

Salt Mist Corrosion Testing Of Photovoltaic PV Modules

Nov 01, 2022

salt mist corrosion testing of photovoltaic pv modules

The purpose of salt-spray corrosion test is to determine the salt mist corrosion testing of photovoltaic pv modules. Salt spray corrosion test can be used to evaluate the adaptability of PV module materials and the quality and uniformity of the protective layer.


Salt spray corrosion tests can assess the adaptability of PV module materials, the quality and uniformity of the protective layer.


LIB salt spray test chamber meets the PV salt spray test conditions

Temperature  Range

+10 ℃ ~ +90 ℃

Temperature Fluctuation

± 0.5 ℃

Temp. Deviation

± 2.0 ℃

 Humidity Range

30% ~ 98% RH

Humidity Deviation

+ 2%, - 3%

Salt Fog Deposition

1~2ml / 80cm2 · h

Controller

Programmable color LCD touchscreen controller

Environmental Conditional

5℃~+35 ℃   ≤85% RH

 

1. The inclination Angle between the upper surface of the sample placement component and the vertical direction should be 15° to 30°.


2.The duration of the test was 96h


3.Each group can arbitrarily set a partial cycle of 1-999 times or a full cycle of 1-999 times.


salt mist corrosion testing of photovoltaic pv modules 4.jpg
salt mist corrosion testing of photovoltaic pv modules2.jpg
salt mist corrosion testing of photovoltaic pv modules3.jpg



Send Inquiry