+8618700875368

UV Chamber For Preconditioning Test

Jan 10, 2023

IEC 61215 specifies design validation requirements for terrestrial photovoltaic modules suitable for long-term operation in open-air climate conditions. The service life of a qualified component depends on its design, environment and operating conditions.

 

The UV Chamber For Preconditioning Test is a photovoltaic panel UV preconditioning test chamber according to the IEC 61215 (MQT 10) standard.

UVpreconditioningchamber31

LIB UV Preconditioning Chamber


According to the customer's requirements, LIB specially customized the UV test chamber for testing photovoltaic panels for German customers

 

Custom Content

UVpreconditioningchamber28 Sample Holder
Allows the sample to be evenly exposed to the UV condition;
Two Sample holders are installed in the chamber with each size is 2384x1303mm
Sample holders is adjustable, to fix different size panel, easy to load samples
The distance from the sample holder the lamp can be adjustable.
UVpreconditioningchamber26

UV lamps

Chamber equipped with 27pcs of UV lamp, included 18 pcs of UVA lamps and 9 pcs of UVB lamps

Installed in the middle of the chamber,

Irradiance 15KW.H/M2 at 280nm ~ 385nm

Irradiance At least 5KW.H/M2 at 280nm ~ 320nm

280nm ~ 385nm Irradiance < 250 w/m2

UVpreconditioningchamber24

Core Function

The PID controller as the main control unit to command, operate, detect and redistribute the various components of the equipment to achieve maximum effective use.

Screen display function: LCD display, which can display test conditions including temperature,black panel temperature and irradiance and time.

 

Send Inquiry