+8618700875368

IPX1 IPX2 Environmental Chamber

Dec 27, 2022

How are LIB IPX1 IPX2 Environmental Chamber classified?

 

●The grade of LIB IPX1 rain test chamber

1. Method name: vertical dripping test;

2. Test equipment: drip test device and test method;

3. Placement of the sample: Place the sample on the rotating sample stage at 1r/min according to the normal working position of the sample, and the distance from the drip hole on the top of the sample is not more than 200mm;

4. Test conditions: dripping water is 1.0+0.5mm/min;

5. Test duration: 10 minutes.

page-395-275

 

●The grade of LIB IPX2 rain test chamber

1. Method name: 15° inclined water drip test;

2. Test equipment: drip test device and test method;

3. Sample placement: Make one of the samples form an angle of 15° with the vertical line, and the distance from the top of the sample to the drip hole is not more than 200mm. After each test on one side, change the other side, four times in total;

4. Test conditions: dripping water is 3.0+0.5mm/min;

5. Test duration: 4x2.5min for a total of 10min.

page-395-275

page-375-211

 