UL 50E rain spray test chamber main test enclosures for electrical equipment, Environmental Consideralions
This standard applies to enclosures for electrical equipment intended to be installed and used in nonhazardous locations in accordance with the Canadian Electrical Code, Part I, CSA C22.1, the provisions of the National Electrical Code, NFPA 70, and the provisions of Mexico's Electrical Installations, NOM-001- SEDE.
Structure
LIB provides UL 50E rain spray test chamber that can conform to the UL 50Estandard

Advantages
1.Overall Dimensions:800*1500*2200mm
2.Height adjustment range of spray device:1000-2000mm
3.Number of spray head:4 spray heads(There are 3 spray heads on the top and 1 4.spray nozzle on the bottom)
5.Nozzle spacing:710mm
6.Spraying Hole Diameter:Φ5mm
7.Water pressure:34.5Kpa
8.Sample platform size:500X1500X500
9.Load of sample platform load:100 Kgs
10.Water Pressure Control:Flow meter
11.Automatic water supply, Water purification system