MIL-STD-810H METHOD 510 Dust And Sand Test Chamber
Interior Volume:1000L;
Air velocity: 1.5 -8.9m/s;
Concentration of dust:10.7±7g/ m³;
Dust particles : < 150μm;
Air velocity: 18.0 -29.0m/s;
Concentration of sand:0.18+0.2g/m³;
Sand particles:149μm - 600μm, 600μm - 850μm;
Name:Dust and sand test chamber
Description
Xi'an LIB Environmental Simulation Industry is one of the most reliable manufacturers and suppliers of mil-std-810h method 510 dust and sand test chamber in China, featured by quality products and low price. Welcome to buy CE approved mil-std-810h method 510 dust and sand test chamber in stock here and get quotation from our factory. Contact us for discount information.
MIL-STD-810H METHOD 510 Dust and sand test chamber is used for evaluating the resistance of a system to dust and sand particles in accordance with MIL-STD-810g.
Specifications
Model | DIM-1000 |
Internal Dimension | 1000*1000*1000mm D*W*H |
Overall Dimension | 2800*3500*2000mm D*W*H |
Interior Volume | 1000L |
Blowing Dust | |
Air velocity | 1.5 -8.9m/s |
Concentration of dust | 10.7±7g/ m³ |
Dust particles | < 150μm |
Blowing sand | |
Air velocity | 18.0 -29.0m/s |
Concentration of sand | 0.18+0.2g/m³; 1.1+0.3g/m³; 2.2+0.5g/m³ |
Sand particles | 149μm - 600μm, 600μm - 850μm |
Controller | Programmable color LCD touch screen controller |
Door Lock | Electromagnetic lock |
Testing Platform Diameter | 600mm |
Testing Platform Speed | 1-7 r.p.m |
Dust Detector | Integrated dust detector |
Dust collection and cleaning | Equipped with a vacuum cleaner interface, an electric vibrator is installed on the entire air duct and the wall of the test chamber, which can shake off and disperse the dust absorbed on the wall. |
Exterior Material | A3 Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
Power Supply | 380V 50Hz |
Maximum Noise | 65 dBA |
Standard | MIL-STD- 810g |
Design Detail
![]() | |
| Workroom | Viewing Window |
![]() | |
| Large Centrifugal Fan | Wind Speed Sensor |
The Purpose of Dust (< 150μm) Procedure
Dust and sand test equipment,This test procedure is performed to assist measure the flexibility of equipage to resist the results of mud that will hinder openings, penetrate into cracks, crevices, bearings, and joints, and to judge the effectiveness of filters.
Sand (150 to 850μm particle size) Procedure
Blowing sand test equipment,The Sand (150 to 850μm particle size) procedure is performed to assist measure the flexibility of equipage to be hold on and operated in processing sand conditions while not degrading performance, effectiveness, responsibility, and maintainability because of abrasion (erosion) or preventive effects of huge, sharp-edged particles.
Features
*Temperature
10℃~80℃
*Blowing Dust
10.7±7g/ m³
*Blowing Sand
0.18+0.2g/m³; 1.1+0.3g/m³; 2.2+0.5g/m³
Large Centrifugal Fan
Wind Speed Control
Dust Concentration Control
Internal illumination in test room
Dust sand test machine,Safety protection system