Sep 09, 2025

When testing materials for outdoor durability, accurate simulation of sunlight, heat, and moisture is critical. A Xenon test chamber replicates natural sunlight using full-spectrum xenon arc lamps, delivering repeatable, standards-compliant accelerated aging results for plastics, coatings, films, and automotive components.

 

LIB's Xenon Arc Weatherometer meets international standards, including ASTM G151, D6695, G155, ISO 11341, and D7869, ensuring reliable testing and traceable data.

 

Xenon Wetherometer

Xenon Wetherometer

Sample holder

Adjustable speed, 1r /min

Chamber Type

Rotating Holder

Irradiation Source

4500w water-cooled xenon arc lamp with inner quartz and outer borosilicate filter

Irradiance Range

35~150 W/㎡

Bandwidth Measurement

280~800 nm

Chamber Temperature Range

Ambient~ 100 ℃ ±2 ℃

Black Panel Temperature

BPT 35 ~ 85 ℃ ±2 ℃

Humidity Range

50 % ~ 98 % RH

Water Spray Cycle

1~9999 H 59 M (Adjustable)

 

1

Working Principle of Xenon Test Chambers for Realistic Sunlight Simulation

 

Xenon test chambers use water-cooled xenon arc lamps to mimic natural sunlight across the 280–800 nm spectrum, including UV, visible, and infrared radiation. Key operational features include:

 

Light Control: 4500 W xenon lamps with real-time radiometer feedback deliver uniform irradiance across up to 42 flat or custom samples. Optional daylight, window-glass, and extended UV filters allow precise simulation of different sunlight conditions.

Xenon Arc Weatherometer

xenon lamp and filters

Temperature Control: Black Panel Temperature (BPT) is maintained between 35–85 °C (±2 °C) and Chamber Air Temperature (CAT) ranges from 35–50 °C, ensuring consistent degradation rates.

Xenon Arc Weatherometer

 

Humidity & Spray Cycles: Adjustable 30–98 % RH with automated filtered water sprays simulating dew and rain. A closed-loop water recovery system saves up to 80 % of water.

xenon chamber (32)

Rain spray system

Rotating Sample Holders (customizable): Flat-panel holders accommodate large or irregular samples without compromising uniformity.

This system guarantees repeatable, standards-compliant results for outdoor-exposed materials.

 

 

Xenon Wetherometer Xenon Wetherometer

 Rotating sample holder

 

2

Exceptional Capability of Xenon Test Chamber for Accelerated Aging to Evaluate Coatings According to ASTM G151

 

ASTM G151 specifies a method for accelerated aging exposure testing of nonmetallic materials using laboratory light sources, emphasizing that laboratory test conditions should replicate the aging trends of materials in actual outdoor environments as closely as possible. The standard explicitly states that laboratory testing is primarily used to compare the relative durability of materials and consistency between batches, and cannot directly substitute for real-world outdoor service life evaluation.

 

The LIB Xenon Arc Test Chamber strictly adheres to ASTM G151-19, enabling precise control of light intensity, temperature, humidity, and spray cycles to ensure stable, repeatable, and comparable material test results. Based on the standard's typical exposure conditions, the LIB test chamber achieves the following control parameters:

 

Light Intensity and Wavelength Control: Provides irradiance ranging from 0.30–1.10 W/m²·nm, covering wavelengths from 340–420 nm. Supports Daylight and Window Glass filters to simulate various daylight conditions.

 

Black Panel Temperature and Humidity Cycling: Maintains black panel temperatures from 63–77°C, paired with relative humidity cycles from 35–70%.

 

Flexible Exposure Cycles: For example, 102-minute illumination + 18-minute spray cycle, or 1.5-hour illumination + 0.5-hour spray cycle.

 

Configurable Dark Periods and Humidity Variations: Such as 6 hours dark + 95% RH, or 1 hour dark + 90% RH, precisely simulating real-world environments.

 

The LIB Xenon Arc Test Chamber precisely controls light intensity, wavelength, black panel temperature, humidity, and spray cycles to fully comply with ASTM G151-19 standards. It delivers reliable, repeatable, and customizable laboratory solutions for accelerated aging testing of coatings, plastics, and automotive materials, enabling R&D and quality control teams to conduct efficient, scientific durability evaluations.

 

 

3

LIB Xenon Test Chamber and UV Test Chamber Available for Selection

 

Choosing between a Xenon Arc Chamber and a UV Test Chamber depends on the material and testing purpose:

  Xenon Arc Weatherometer Xenon Arc Weatherometer
Feature Xenon Arc Chamber UV Test Chamber
Light Spectrum Full 280–800 nm UV-focused 280–400 nm
Applications Outdoor materials, automotive, building products Indoor plastics, packaging, coatings
Environmental Simulation Light, temperature, humidity, and spray cycles UV irradiation with optional humidity or condensation

Recommendation: Use a Xenon Arc Chamber for full sunlight simulation, such as automotive parts, outdoor coatings, and plastics. Choose a UV Chamber for UV-only degradation or preliminary R&D testing.

 

Why LIB?

Standards Compliance: ASTM G151, D6695, G155, ISO 11341, D7869,etc.

Precision & Reliability: ±2 °C BPT, ±2.5 % RH, real-time irradiance monitoring

Customizable & Flexible: Sample holders, spray systems, hydrogen peroxide integration

Automation & Traceability: PID control, programmable profiles, remote monitoring, automated data export (CSV/PDF)

Sustainability & Efficiency: Closed-loop water recovery and energy-efficient lamp cooling

Service & Support: 3-year warranty, lifetime maintenance, 24/7 English-speaking support, 7–15 days shipping

 

LIB Xenon Arc Weatherometer accelerates outdoor material testing without compromising accuracy, providing repeatable, standards-aligned, and fully customizable solutions for faster, safer, and more reliable durability validation.

 

Contact LIB Insdustry to get your exclusive Xenon and UV testing solutions.

Send Inquiry