LIB Industry designs and manufactures walk in chambers including integrated type and disassembling type.
With large volume, the chamber can be used to simulate the single or complicated environmental factors in the atmosphere such as temperature, humidity, salt fog, UV, dust, rain and vibration. The walk-in climatic chamber becomes the best choice for testing these large components.
What is the walk-in climatic chamber?
Walk-in climatic chamber is specifically designed to perform temperature and humidity tests on products and materials to ensure that they meet certified safety and performance requirements. Walk-in climatic chamber is designed with a variety of necessary functions required to test the safety, performance for heat, cooling, and moisture resistance. And it comes in different sizes, and is usually customized according to the customer's needs.
Common test items for walk-in climatic chamber:
What are the features of the walk-in climatic chamber?
Accurate temperature control, high precision. Due to the use of special air duct system design and electronic control system, the temperature uniformity of the whole room can be maintained, which is conducive to the accuracy of future experiments.
The Laboratory structure design is advanced and reasonable, supporting products and functional components can meet the safe and reliable production needs of the climatic chamber.
The System Protection function is complete, can ensure long-term safe, stable and trouble-free operation.
The severity of high and low temperature test depends on what ?
The severity of the high and low temperature test (performed in the walk-in climatic chamber) depends on the test temperature grade and duration, the relevant standards should be selected from the following values: -70, -65, -55, -40, -25, -10, -5, +5℃ (the allowable deviation range of test temperature is ±2℃) After the temperature of the test sample has reached stability, if a certain time of low temperature test, its duration should be given priority.
If the purpose of the test is only to check whether the test sample can work at low temperatures, the time of the test is limited to a stable temperature of the test sample, and in any case the duration should not be less than 30 minutes.
Whether the test temperature of the workroom is uniform is a key problem, if the temperature is not uniform and beyond the allowable deviation, the test conditions of the sample can not reach the same, a part of the sample, some test temperature is high, some is low, resulting in poor reproducibility of the test, the test data is not reliable, the test results are attributed to failure.

Walk-in TH

Walk-in TH
XI'an LIB walk-in climatic chamber is specially developed for large test products that cannot be tested in standard size test chambers. With this walk-in climate simulation test chamber, various temperature and humidity tests can be carried out in the fields of R&D, production and quality control, as well as efficient and homogeneous temperature and humidity regulation in the test chamber to achieve constant temperature and humidity. And the test results are guaranteed to be reproducible regardless of the shape and type of the test sample. In addition, it can accurately control the airflow according to the set temperature and humidity setting values, to ensure that the airflow in the whole test chamber is constant and consistent.