SO2 Corrosion Test MachineSO2 Corrosion Test Machine;. Temperature: 15℃~80℃;. Humidity: 30%~98%RH;. SO2 Concentration: 25±5 ppm;. Air Change Rate: 3~5 /h;. High Accuracy Gas Sensor;. Gas Exhaust Device;. Cilicone Sealing;.
Add to Inquiry
SO2, H2S, NO2, Cl2 Atmospheric Corrosion Test EquipmentName: SO2, H2S, NO2, Cl2 Atmospheric Corrosion Test Equipment;. Material: SUS 316 stainless steel plate in inner;. SO2 Concentration: 100 ~500 ppb± 20 ppb (Adjustable);. H2S Concentration: 10 ~100
Add to Inquiry
Mixed Gas ChamberTemperature: 15℃~80℃;. Humidity: 30%~98%RH;. SO2 Concentration: 25±5 ppm;. Air Change Rate: 3~5 /h;. High Accuracy Gas Sensor;. Gas Exhaust Device;. Cilicone Sealing;. Electromagnetic Lock;.
Add to Inquiry
Gas Corrosion Test ChamberName:gas corrosion test chamber. Temperature:15℃~80℃;. Humidity;30%~98%RH;. SO2 Concentration:25±5 ppm;. Gas Exhaust Device;. Custom and Standard
Add to Inquiry
IEC 60068-2-43 Test ChamberIEC 60068-2-43 test chamber;. Temperature: 15℃~80℃;. Humidity: 30%~98%RH;. SO2 Concentration: 25±5 ppm;. Air Change Rate: 3~5 /h;. High Accuracy Gas Sensor;. Gas Exhaust Device;. Cilicone Sealing;.
Add to Inquiry
Noxious Gas Flow ChamberLIB Noxious Gas Flow Chamber's workroom has a two-layer design. The inner layer of the studio of this product is SUS304 steel plate, and the outer layer is made of highly corrosion-resistant FRP,
Add to Inquiry
Noxious Gas Test EquipmentNoxious Gas Test Equipment;. Temperature: 15℃~80℃;. Humidity: 30%~98%RH;. SO2 Concentration: 25±5 ppm;. Air Change Rate: 3~5 /h;. High Accuracy Gas Sensor;. Gas Exhaust Device;. Cilicone Sealing;.
Add to Inquiry
CO2 Climate Test EquipmentTemperature: 15℃~80℃;. Humidity: 30%~98%RH;. SO2 Concentration: 25±5 ppm;. Air Change Rate: 3~5 /h;. High Accuracy Gas Sensor;. Gas Exhaust Device;. Cilicone Sealing;. Electromagnetic Lock;.
Add to Inquiry
H2S Noxious Gas Test EquipmentTemperature: 15℃~80℃;. Humidity: 30%~98%RH;. SO2 Concentration: 25±5 ppm;. Air Change Rate: 3~5 /h;. High Accuracy Gas Sensor;. Gas Exhaust Device;. Cilicone Sealing;. Electromagnetic Lock;.
Add to Inquiry
Ozone Environmental Test ChamberTemperature: 0℃~+100℃; . Humidity: 30% -98%RH; . Ozone Concentration: 1~1000PPHM; . Clamps Tensile Stretch: 5%~35%;. Dry and Wet Bulb Sensor;. Static+dynamic Combined Sample Holder;. Free
Add to Inquiry
Rubber Ozone Testing EquipmentTemperature: 0℃~+100℃; . Humidity: 30% -98%RH; . Ozone Concentration: 1~1000PPHM; . Airflow Rate: 0 ~ 60L/min;. Ozone Generator;. Water Supply System;. Comply with ISO1431; ASTM1149; IEC60903;
Add to Inquiry
HCL Corrosion Noxious Gas Test ChamberTemperature: 15℃~80℃;. Humidity: 30%~98%RH;. SO2 Concentration: 25±5 ppm;. Air Change Rate: 3~5 /h;. Sensor Control Accuracy: ± 0.1% FSGood Aealing Performance;. Electromagnetic Lock;. CE ROHS
Add to Inquiry