The IP protection level test mainly assesses whether the shell of various equipment has the ability to prevent dust and water from entering, Ip65 Test Equipment assesses whether the sealing performance of the shell is intact
IP65 waterproof and dustproof test requirements IP6X means dustproof test, which requires completely preventing dust from entering;
IPX5 represents the water spray test, which requires the product to be sprayed with water on each surface without water droplets entering the product.

IP6X:DI-800

IPX5:R56-800
Parameters of LIB IP Test Chamber
|
Model |
IP6X:DI-800 |
|
Temperature Range |
Ambient ~ +50℃ |
|
Humidity Range |
< 30% RH |
|
Normal Wire Diameter |
50um |
|
Nominal Width of a Gap Between wires |
75um |
|
Fight Time |
0 ~ 99H59M |
|
Blowing Time |
0 ~ 99H59M |
|
Specimen Power Outlet |
Dust-proof socket 16A |
|
Vacuum System |
Equipped with a pressure gauge, air filter, pressure regulator, connecting tube |
|
Door Lock |
Electromagnetic lock |
|
Standard |
IEC 60529, ISO 20653 |
|
Model |
IPX5:R56-800 |
|
Diameter of Turntable (mm) |
600 |
|
Turntable loads |
20kgs Max |
|
Turntable Rotation Speed |
0~7r/min (Adjustable) |
|
Internal Diameter of IPX5 Nozzle |
6.3mm |
|
Internal Diameter of IPX6 Nozzle |
12.5mm |
|
Water Flow Rate IPX5/ IPX6 |
12.5L/min ±5% / 100L/min ±5% |
|
Water Supply System |
Water tank, booster pump, Automatic water supply, Water purification system |
|
Standard |
IEC 60529, ISO20653 |