Contact Us
+8618700875368
No.6 Zhangba First St, Xian High-Tech Area, Shaanxi Province
Battery Salt Spray Cabinet
Application:Battery
Humidity Range:30% ~ 98% RH
Temperature Range:+10 ℃ ~ +90 ℃
Heating Element:Nichrome heater
Sealing:Hydrostatic hood seal
Controller:PID controller
Power Supply:220V 50Hz
Name:Battery salt spray cabinet
Description
Xi'an LIB Environmental Simulation Industry is one of the most reliable manufacturers and suppliers of battery salt spray cabinet in China, featured by quality products and low price. Welcome to buy CE approved battery salt spray cabinet in stock here and get quotation from our factory. Contact us for discount information.
Battery salt spray cabinet ,The salt spray corrosion test is performed on the battery to ensure that the power battery is not affected in the salt spray environment and provides a stable power supply.
Video
Parameter
| Name | Battery Salt Spray Cabinet | |
Model | SC-010 | SC-016 |
Internal dimensions (mm) | 800*1450*680 | 1000*1600*800 |
Overall dimensions (mm) | 1400*2500*1720 | 1600*2650*1840 |
Interior Volume (L) | 780 | 1280 |
Temperature Range | +10 ℃ ~ +90 ℃ | |
Temperature Fluctuation | ± 0.5 ℃ | |
Temperature Deviation | ± 2.0 ℃ | |
Humidity Range | 30% ~ 98% RH | |
Humidity Deviation | + 2%, - 3% | |
Salt Fog Deposition | 1~2ml / 80cm2 · h | |
Sealing | Pneumatic seal | |
Controller | Programmable color LCD touch screen controller, Ethernet connection, PC Link, USB | |
Material | Glass fiber reinforced plastics | |
Power Supply | 380V 50Hz | |
Battery Salt Spray Test
![]() | Requirements: There is no leakage, shell crack, fire or explosion in the battery pack or system. |
The salt solution is prepared with sodium chloride and distilled or deionized water
Battery Salt spray test chamber
● The concentration is: 5±0.1%.
● Temperature: measured at 20±2℃
● The PH value is between 6.5 and 7.2.
Salt Spray Test of Battery
Battery salt testing equipment
1.Put the test object into the salt spray device and spray the salt spray at 15℃~35℃ for 2h.
2. After spraying, transfer the test object to a hot and humid chamber for 20h-22h, with a temperature of (40±2)℃ and a relative humidity of (93±3)%, forming a cycle.
3. Cycle 3 times, and then store for 3 days under the test standard atmospheric temperature of (23±2)℃ and relative humidity of 45%~55% to form a cycle.
4. Repeat the test for 4 cycles.

● More Battery solution ,please contact us
Hot Tags: battery salt spray cabinet, manufacturers, suppliers, factory, cost, price, used, specification, for sale, B117 Salt Spray Corrosion Test Chamber, cct chambers, Photovoltaic Panels Salt Cycle Equipment, Salt Mist Test Facility, salt spray corrosion test cabinet, Solar PV Salt Spray Testing Device