Contact Us
+8618700875368
No.6 Zhangba First St, Xian High-Tech Area, Shaanxi Province
PV Panel Temperature Change Test ChamberApplication:PV Panel;. Relative Humidity:85%±5%;. Test Temperature: 85℃±2℃;. Test Duration:1000h;. Temperature Change Rate:1~3.4 ℃ / min;. Free calibration
Add to Inquiry
PV Test ChamberApplication:PV Panel;. Relative Humidity:85%±5%;. Test Temperature: 85℃±2℃;. Test Duration:1000h;. Temperature Change Rate:1~3.4 ℃ / min;. Free calibration
Add to Inquiry
AGREE Vibration Test ChamberTemperature Range: -50℃ ~ +150 ℃;. Humidity Range: 30% ~ 98% RH;. Dynamic diameter: ¢240mm;. Max load: 500kgs;. Air Circulation: Centrifugal wind fan;. Interior Material: SUS304 stainless steel;.
Add to Inquiry
High Low Temperature Test ChamberName:High low temperature test chamber;. Model: TH-800;. Interior Volume: 800L;. Temperature Range: -20℃~ +150 ℃;. Temperature Fluctuation: ± 0.5 ℃;. Humidity Range: 20% ~ 98% RH;. Maximum Noise
Add to Inquiry
Battery Testing ChamberName:Battery testing chamber;. Temperature Range:-70°C~+150°C;. Model: TH-225;. Refrigerant: R404A, R23;. Temperature Fluctuation: ± 0.5 ℃;. Heating rate:3 ℃ / min;. Temperature deviation:± 2.0 ℃;.
Add to Inquiry
high temperature test equipmentName:high temperature test equipment;. Temperature Range:-70 °C~+150 °C;. Refrigerant: R404A, R23;. Temperature Fluctuation: ± 0.5 ℃;. Heating rate:3 ℃ / min;. Temperature deviation:± 2.0 ℃;.
Add to Inquiry
PV Module Test ChamberName:PV Module Test Chamber. Interior Volume: 1220L . Temperature Range: -60℃ ~ +100 ℃. Humidity Range: 20% ~ 98% RH. Temperature Change Rate: 1 ~ 3.4℃ / Min. Panel Capacity: 4 / 6 / 8 / 10 / 12
Add to Inquiry
Deep Freezertemperature range: -120℃ ~ +150℃;. application: aerospace, military, electronic. Controller:Programmable controller ;. Temperature Fluctuation: ± 0.5 ℃;. Timing Function: 0.1~999.9 (S、M、H) ;.
Add to Inquiry
Condensation Climate Test ChamberTemperature Range: 10℃ ~ +60 ℃;. Humidity Range: 95%RH ~ 100%;. Sample shelf:1pc sample shelf + 1pc round bar ;. Water trough: Build-in water trough in testing room;. Controller: Ethernet connection,
Add to Inquiry
Controlled RH 100% Laboratory Climate ChamberTemperature: -70℃~+150℃;. Humidity: 20%~98%RH;. Volume: 100L, 225L, 500L, 800L, 1000L;. Cooling Rate: 1 ℃ / min;. Heating Rate: 3 ℃ / min;. Cooling system: compression refrigeration system;.
Add to Inquiry
Industrial Heating Drying Oven6℃/min Fast Heating Rate;. High Temperature Can Up To 900℃;. PT100Ω/MV A-class temperature sensor;. Over-temperature Protection; Over-current Protection;Earth leakage Protection;. Standard &
Add to Inquiry
Constant Temperature And Humidity Test ChamberTemperature Range: -86℃~150℃;. Humidity Range: 10% - 98% RH;. Heating Rate: 3℃/minute;. Type: Benchtop, floor stand & walk in;. Free calibration;. Reliable manufacturer;. Stock and free ship;.
Add to Inquiry





